Product information
Product[

Cleanert SUL-5

]Data
If you are interested in this product, you can Product Name: Cleanert SUL-5
Product Model: SUL-5
Product exhibitors: Agela
Brief:

Specific SPE column for Sulfonamides SUL-5(Specific SPE column for Sulfonamides) is specially designed for the extraction of five



Cleanert SUL-5Detailed description of

 

sulfonamides (SM2, SMM,SMZ, SDM, SQ) in pork.

Material
Sorbent
Vol
Tube/Box
Part.No
Cleanert SUL-5
2g
12ml
100
SUL-5

 
Cleanert DNPH-Silica
Specialized for Pretreatment of Aldehydes and Ketones in Air

Meterial
Sorbents
Vol
Tubes/Box
Part.No
DNPH-Silica
200mg
3mL
1
DN2003
200mg
1mL
1
ICDN2001

 
Cleanert TPH
TPH means triple phase SPE for Herb, and it was constituted by three kinds of materials. These three kinds of materials using different mechanism of action, focus on the colorants, organic acid and organic substance, also cosidering different polarity of the interferent, such as nonpolarity substance, substance with hydroxyl and carboxyl group, also the basic group. By mixing different materials together, we achieve a better result of clean up, expecially complicated matrix.
TPH is majorly used for extraction and detection of pesticides from ChineseHerb such as Ramulus Mori, Honeysuckle and the Fruit of Chinese Wolfberry, It can absorb reduce up to 80% interferent and without adsorb any pesticide residues.
Cleanert TPH has been used in China national standard methods, Determination of 488 Pesticide Residues and Related Chemicals Residues and 413 Pesticide Residues and Related Chemicals Residues in the Ramulus Mori, Honeysuckle and the Fruit of Chinese Wolfberry with GS-MS and LC-MS/MS Respectively, Determination of 448 pesticides and related chemicals residues in tea—LC-MS-MS method. The process mainly containing ACN extraction, Load the sample on the pre-actived column, and then eluted by ACN- toluene (3+1).

Meterial
Sorbents
Vol
Tubes/Box
Cat.No
Cleanert TPH
2g
12mL
20
TPH200010
1g
6mL
30
TPH0006

 
Cleanert TPT
TPT was constituted by three kinds of materials. These three kinds of materials using different mechanism of action, focus on the colorants, organic acid and tea polyphenols, also considering different polarity of the interferent, such as nonpolarity substance, substance with hydroxyl and carboxyl group, also the basic group. By mixing different materials together, we achieve a better result of clean up, expecially complicated matrix. TPT is majorly used for extraction and detection of pesticides from tea leaf, It can adsorb reduce up to 80% interferent and without adsorbing any pesticide residues.

Meterial
Sorbents
Vol
Tubes/Box
Cleanert TPT
2g
12mL
20
TPT200010
1g
6mL
30
TPT0006

 
Matrix Solid Phase Dispersion-extractionMSPD

Product Name
Specification
Cat.No
NY1380-2007 Methods package
One set
NY1380-2007
                               Price itemized
 
Cleanert PSA Adsorbent
100g
PA0010
Cleanert C18 Adsorbent
100g
180100
Anhydrous magnesium sulfate
500g
7487-88-9

 
Textiles disable azo dyes Pre-treatment Methods package

Meterial
The amount of filler
Volume
Wrapper
Cat.No
Cleanert(Diatomaceous earth extraction columns)
20g
60mL
1
GB/T17592-2006
Product Name
Specification
Cat.No
DA-5MS  Capillary gas phase column
30m×0.25mm×0.25μm
1525-3002
Venusil MP C18
4.6mmX250mm
VA952505-0

 
Cleanert SLE

Specification
Volume
PackingSpecification
Cat.No
100mg
1mL
100
HC1001
200mg
3mL
50
HC2003
500mg
3mL
50
HC5003
500mg
6mL
30
HC5006
1000mg
6mL
30
HC0006
100g
 
Bottle
HC0100
1000g
 
Bottle
HC1000
200mg
2mL
96-well Plates
HC2002-W
400mg
2mL
96-well Plates
HC4002-W
500mg
2mL
96-well Plates
HC5002-W

 
Cleanert BaP

Product Name
Specification
Cat.No
Packing
Cleanert BaP
(Benzopyrene-solid-phase extraction Dedicated column)
22g/60mL
BaP2260
10/pack
Venusil PAH
(PAHDedicated column)
4.6*250,5um
VP952505-L
1
Venusil PAH Guard Cartridges
4.6*19,5um
VP95105-L
1
Guard Cartridges set
CH-100
 
1

 
Cleanert SCX

Average particle size:50µm;Average pore diameter60Å;
Meterial
The amount of filler
Volume
Packing Specification
Cat.No
Cleanert SCX
100mg
1mL
100
SC1001
200mg
3mL
50
SC2003
500mg
3 mL
50
SC5003
500
6 mL
30
SC5006
1g
6 mL
30
SC0006
10g
 
Bottle
SC0010
100g
 
bottle
SC0100
50mg
2 mL
96-well Plates
SC0502-W
100 mg
2 mL
96-well Plates
SC1002-W

 
 
Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!

TEL: 86-020-83939300
Fax: 86-020-81169199
Address:Room 2203, the Pearl River International Building, No. 112, Yuehua Road, Yuexiu District, Guangzhou
Email: support@lubex.com.cn