Product information
Product[

GCMS Columns

]Data
If you are interested in this product, you can Product Name: GCMS Columns
Product Model: 127-0112
Product exhibitors: Agilent
Brief:

100% Dimethylpolysiloxane Identical selectivity to DB-1 Non-polar Very low bleed characteristics, ideal for GC/MS Improved acid performance compared to standard 100% Dimethylpolysiloxane columns



GCMS ColumnsDetailed description of

 

DB-1ms
 
Part Number
ID(mm)
Length(m)
Film (μm)
Temperature limit (º C)
127-0112
0.10
10
0.10
-60 to340/360
127-0113
0.10
10
0.40
-60 to 340/360
127-0122
0.10
20
0.10
-60 to 340/360
127-0123
0.10
20
0.40
-60 to 340/360
128-0112 
0.20
12
0.33
-60 to 340/350
128-0122 
0.20
25
0.33
-60 to 340/350
122-0112  
0.25
15
0.25
-60 to 340/360
122-0131 
0.25
30
0.10
-60 to 340/360
122-0132   
0.25
30
0.25
-60 to 340/360
122-0162   
0.25
60
0.25
-60 to 340/360
123-0112   
0.32
15
0.25
-60 to 340/360
123-0131 
0.32
30
0.10
-60 to 340/360
123-0132 
0.32
30
0.25
-60 to 340/360
123-0162   
0.32
60
0.25
-60 to 340/360
HP-1ms
100% Dimethylpolysiloxane
Identical selectivity to HP-1
Non-polar
Low bleed characteristics
Excellent general purpose column
Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
Bonded and cross-linked and solvent rinsable
 
 
 

Part Number     ID(mm)       Length(m)         Film (μm)     Temperature  limit (º C)
19091S-602        0.20              25            0.33                      -60 325/350
19091S-931        0.25              15            0.25                      -60 325/350
19091S-833        0.25              30            0.10                      -60 325/350
19091S-933        0.25              30            0.25                      -60 325/350
19091S-633        0.25              30            0.50                      -60 325/350
19091S-733        0.25              30            1.00                      - 60 325/350
19091S-936        0.25              60            0.25                      -60 325/350
19091S-911        0.32              15            0.25                       -60 325/350
19091S-612        0.32              25            0.52                      -60 325/350
19091S-913        0.32              30            0.25                      -60 325/350 
19091S-713        0.32              30            1.00                       -60 325/350
19091S-916        0.32              60            0.25                       -60 325/350

 
 
DB-5ms
Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane
Non-polar
Very low bleed characteristicsm, ideal for GC/MS
Excellent inertness for active compounds
Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
MSD testing and certification available
Exact replacement of HP-5TA
Close equivalent to USP Phase G27
Available with DuraGuard (GC column with a built-in guard column)
Part NO.
ID(mm) (mm)
Length(m)
Film (μm)
Temperature limit (º C)
121-5522
0.18mm
20m
0.18μm
-60~340/360
121-5542
0.18mm
40m
0.18μm
-60~340/360
128-5512
0.20mm
12m
0.33μm
-60~340/360
128-5522
0.20mm
25m
0.33μm
-60~340/360
128-5552
0.20mm
50m
0.33μm
-60~340/360
122-5511
0.25mm
15m
0.10μm
-60~340/360
122-5512
0.25mm
15m
0.25μm
-60~340/360
122-5513
0.25mm
15m
1.00μm
-60~340/360
122-5522
0.25mm
25m
0.25μm
-60~340/360
122-552A
0.25mm
25m
0.40μm
-60~340/360
 
HP-5ms
(5%-Phenyl)-methylpolysiloxane
Non-polar
Very low bleed characteristics, ideal for GC/MS
Excellent inertness for active compounds including acidic and basic compounds
Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
Bonded and cross-linked; solvent rinsable
Equivalent to USP Phase G27
Part NO.
ID(mm) 
Length(m)
Film (μm)
Temperature limit (º C)
19091S-101
0.20mm
12m
0.33μm
-60~325/350
19091S-102
0.20mm
25m
0.33μm
-60~325/350
19091S-105
0.20mm
50m
0.33μm
-60~325/350
 
HP-5ms Semivolatile
Part NO.
Inner diameter (mm)
length(m)
Film (μm)
Temperature limit (ºC)
19091S-139
0.25
30
0.50
-60 至325/350
 
HP-5Msi
To meet the world wide drive to lower detection levels, Agilent offers the HP-5MSi Advanced Inertness MS column. This new capillary column complements Agilent’s 5973 Inert source MS system. The HP-5MSi is specially tested to ensure area response performance of a strong acid and a strong base very low levels on column. It is compatible with Agilent Pesticide Libraries for MS and GC; and all methods developed with HP-5MS, with the same demanding specifications for bleed, RI, CE, and k
Excellent for trace level analysis of acids and bases, such as Semi-volatiles analysis
(5%-Phenyl)-methylpolysiloxane, identical selectivity to HP-5MS
Specifically tested for inertness for active compounds including acidic and basic compounds
Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
Non-polar
Very low bleed characteristics, ideal for GC/MS
Bonded and cross-linked
Solvent rinsable
Equivalent to USP Phase G27
Part NO.
Inner diameter (mm)
length(m)
Film (μm)
19091S-433I
0.25
30
0.25
 
 
 
 
 
 
 
 
DB-35ms:      
Excellent inertness for active compounds 
Virtually equivalent to a (35%-Phenyl)-methylpolysiloxane
Midpolarity
Very low bleed characteristics
Extended temperature limit of 340/360°C
Excellent inertness for active compounds
Ideal for confirmational analyses
Bonded and cross-linked and solvent rinsable
Close equivalent to USP Phase G42
Part NO.
Inner diameter (mm)
Length(m)
Film (μm)
Temperature limit (º C)
128-3812
0.20mm
15m
0.33μm
50~340/360
128-3822
0.20mm
25m
0.33μm
50~340/360
122-3812
0.25mm
15m
0.25μm
50~340/360
122-3831
0.25mm
30m
0.15μm
50~340/360
122-3832
0.25mm
30m
0.25μm
50~340/360
122-3862
0.25mm
60m
0.25μm
50~340/360
123-3812
0.32mm
15m
0.25μm
50~340/360
123-3832
0.32mm
30m
0.25μm
50~340/360
123-3862
0.32mm
60m
0.25μm
50~340/360
125-3837
0.53mm
30m
0.50μm
50~340/360
125-3837
0.53mm
30m
1.00μm
50~340/360
 
 Enhanced mass spectral integrity 
Virtually equivalent to (50%-Phenyl)-methylpolysiloxane
320/340 °C upper temperature limit
Very low bleed midpolarity, ideal for GC/MS
Excellent inertness for active compounds
Enhanced mass spectral integrity
Bonded and cross-linked and solvent rinsable
Best column for CLP pesticides
Part NO.
Inner diameter (mm)
Length(m)
Membrane thickness (μm)
Temperature limit (º C)
121-4722
0.18mm
20m
0.18μm
40~320/340
122-4711
0.25mm
15m
0.15μm
40~320/340
122-4712
0.25mm
15m
0.25μm
40~320/340
122-4731
0.25mm
30m
0.15μm
40~320/340
122-4732
0.25mm
30m
0.25μm
40~320/340
122-4762
0.25mm
60m
0.25μm
40~320/340
              
DB-225ms:
Excellent for FAMEs separations
Virtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane
Mid/high polarity
Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs)
Low bleed
Bonded and cross-linked
Solvent rinsable
Close equivalent to USP Phase G19
Part NO.
Inner diameter (mm)
Length(m)
Film (μm)
Temperature limit (º C)
121-2912
0.25mm
15m
0.25μm
40~240
122-2932
0.25mm
30m
0.25μm
40~240
122-2962
0.25mm
60m
0.25μm
40~240
122-2932
0.32mm
30m
0.25μm
40~240
 
DB-XLB:
The DB-XLB column has a unique selectivity and the DB-XLB also features excellent inertness for active compounds. Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
Exceptionally Low Bleed
Low polarity
Extended temperature limit of 340/360°C
Unique selectivity
Excellent inertness for active compounds
Ideal for confirmational analyses
Excellent for pesticides, herbicides, PCBs and PAHs
Ideal for GC/MS; MSD testing and certification available
Solvent rinsable
Part NO.
Inner diameter (mm)
Length(m)
Membrane thickness (μm)
Temperature limit (º C)
121-1222
0.18mm
20m
0.18μm
30~340/360
121-1232
0.18mm
30m
0.18μm
30~340/360
121-1262
0.18mm
60m
0.18μm
30~340/360
128-1212
0.20mm
12m
0.33μm
30~340/360
128-1222
0.20mm
25m
0.33μm
30~340/360
 
 
 
DuraGuard:
Deactivated fused silica tubing is commonly added to the front of an analytical column to act as a guard, contributing to installation hassles, peak shape problems, and leaks associated with unions. To eliminate these problems, DuraGuard columns are made with a single, continuous piece of tubing consisting of a built-in length of deactivated fused silica tubing and an analytical column. Difficult samples, such as pesticides or drugs, can be analyzed without any undesirable contributions from the unions.
Minimize front-end contamination of the column and increase column lifetime
Aid in focusing sample onto the front end of the column for excellent peak shape
Minimize the amount of mass selective detector (MSD) source contamination originating from the column
Part NO.
Stationary phase
Inner diametermm
Lengthm
Membrane thicknessmm
0.25
30
0.25
0.25
30
0.25
0.25
30
0.50
0.25
30
1.00
0.25
60
0.25
0.53
30
0.50
0.25
30
0.25
0.25
30
0.25
0.53
30
3.00
0.53
30
1.00
 

 


 
Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!

TEL: 86-020-83939300
Fax: 86-020-81169199
Address:Rm307, Jin Yang Bldg, No. 148 Xi Wan Rd, Li Wan District, GZ 510160, PRC
Email: support@lubex.com.cn