Systec ZHCR Degassing Dual Stage (DST) Vacuum Pump, Analytical, Bottom Mounted - 9000-1892

]Data
If you are interested in this product, you can Product Name: Systec ZHCR Degassing Dual Stage (DST) Vacuum Pump, Analytical, Bottom Mounted - 9000-1892
Product Model: 9000-1892
Product exhibitors: Systec
Brief:



Systec ZHCR Degassing Dual Stage (DST) Vacuum Pump, Analytical, Bottom Mounted - 9000-1892Detailed description of

Systec ZHCR (Zero Hysteresis / Constant Run) Vacuum Dual Stage Pump, Analytical, bottom mounted - Pump Only

Product Number: 9000-1892

Replaces Part Number: 9000-1130 / 9000-1295 / 9000-1023

The DST Pump with PCB is a vacuum control system for use with degassing chambers. The system includes a dual stage (DST) vacuum pump and a Smart board controller to maintain vacuum levels. There is a connector for optional external LED indicators or error outputs. The prep versions are designed to handle high vapor loads from high flow rate chambers or fluids with low vapor pressure that will cause increased solvent pervaporation through the membrane.

Systec ZHCR Dual Stage (DST) Vacuum Pump Control System Range:

Part Number Description Mounting Scale
Vacuum Degassing Control System - includes Pump, PCB and Air Bleed
9000-1920 Vacuum Control System Bottom Analytical
9000-1921 Vacuum Control System Side Analytical
9000-1922 Vacuum Control System Bottom Prep
9000-1923 Vacuum Control System Side Prep
Pump Only
9000-1892 Vacuum Pump Only Bottom Analytical
9000-1893 (Replaced by 9000-2061) Vacuum Pump Only Side Analytical
9000-1896 Vacuum Pump Only Bottom Prep
9000-1897 Vacuum Pump Only Side Prep

PUMP CONTROL SPECIFICATIONS:

Power Requirements 24 VDC @ 0.75 Amp max. (< 5 Watts consumption average)
Temperature 50 o C or lower when run in ambient conditions (20- 25 o C)
Vacuum Sensor Calibration Accuracy Prep 80 mmHg +/- 5 mmHg Analytical 50 mmHg +/- 5 mmHg
Closed-Loop Control Setpoint 50 mm Hg absolute (analytical) or 80mm Hg (prep) pump runs at high RPM until near setpoint, then speed is varied to maintain a value of setpoint— load independent.
Errors Detected 1 – Pumpdown: Prep — Unable to reach 82 mm Hg in 10 minutes. Analytical — Unable to reach 52mm Hg in 10 minutes.
2 – High Vacuum: Prep — Vacuum > 110 mmHg for more than 6 min. in the running state (after pumpdown). Analytical — Vacuum > 82 mmHg for more than 6 min. in the running state (after pumpdown).
3 – Sensor Signal: Sensor Failure Detected Sensor signal >800 mm Hg or sensor signal <10 mm Hg.
ANALYTICAL VACUUM PUMP TECHNICAL DATA
Air Flow (no vacuum): 650 SCCM @ 400 RPM; 100 SCCM @ 60 RPM
Typical Vacuum Performance: 50 mmHg @ (60±20) RPM (3 SCCM air flow, closed loop)
Pump-down Time: <1 minute (with 4 MINI degassing channels, 50 cc total internal volume)
Pump Head Continuous Purge Air Flow Rate ~12 SCCM
Vacuum Flow Path Materials: 303 Stainless Steel, Polypropylene, PTFE, EPDM Rubber
Expected Lifetime: :>5 years (continuous run @ 60 RPM)
PREP VACUUM PUMP TECHNICAL DATA
Air Flow (no vacuum): 650 SCCM @ 400 RPM; 100 SCCM @ 60 RPM
Typical Vacuum Performance: 80 mmHg @ (80±20) RPM (3 SCCM air flow, closed loop)
Pump-down Time: <1 minute (with 4 MINI degassing channels, 50 cc total internal volume)
Pump Head Continuous Purge Air Flow Rate: : ~30 SCCM
Vacuum Flow Path Materials: 303 Stainless Steel, Polypropylene, PTFE, EPDM Rubber
Expected Lifetime >5 years (continuous run @ 60 RPM)

Tags: Degassers, Degassing Spare Parts, Vacuum Control Systems, Vacuum pumps with control board

 

Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!

TEL: 86-020-83939300
Fax: 86-020-81169199
Address:Room 2203, the Pearl River International Building, No. 112, Yuehua Road, Yuexiu District, Guangzhou
Email: support@lubex.com.cn


Copyright© 2003-2026  Guangzhou Lubex Scientific Instrument Co., Ltd. All rights reserved.